Mitsubishi Electric P-Series systems are built for larger spaces that need dependable heating and cooling. Go Ductless Inc. helps you choose the right setup and installs it with clean work for steady, efficient comfort.
Mitsubishi Electric P-Series systems are a strong choice for commercial properties that need dependable heating and cooling without major ductwork changes. Go Ductless Inc. helps you plan a setup that fits your space, your usage, and your comfort priorities. From offices and retail to equipment areas that need steady temperature control, we focus on clean work, correct sizing, and reliable operation. The goal is simple, consistent comfort you can count on day after day.
Mitsubishi Electric P-Series systems are built for larger spaces that need dependable heating and cooling with efficient control. Go Ductless Inc. recommends P-Series when you need stronger capacity and flexible system options for demanding environments.
These systems are a great fit for offices, retail locations, restaurants, and spaces like server rooms, equipment rooms, and elevator rooms where steady temperatures matter. With the right design and sizing, you get reliable comfort that supports daily operations without major disruption.
If your project is smaller or focused on a few rooms, our Mitsubishi Electric M-Series options may be a better match. We will help you compare both and choose the right solution for your space.
Mitsubishi Electric P-Series offers multiple indoor unit styles, so your system can match the layout of your building and the look you want. Go Ductless Inc. helps you choose the best option based on airflow coverage, ceiling space, and how the rooms are used day to day.
Common choices include wall mounted units for open areas, ceiling cassette units for balanced airflow, and concealed ducted options when you want a cleaner appearance. For larger zones and commercial interiors, these style options make it easier to deliver comfort without bulky equipment in the way.
Once the style is selected, we plan placement, routing, and controls so the installation stays tidy and performance stays consistent. Our goal is a setup that fits the space and works reliably across seasons.
A strong system starts with correct sizing, careful installation, and proper setup. Go Ductless Inc. follows a clean process that includes planning, neat line routing, testing, and a final walkthrough so you know how to use your Mitsubishi Electric P-Series system confidently.
We verify operation and settings before the job is complete, and we focus on details that help protect performance over time. That includes correct placement, stable mounting, and airflow planning that supports steady comfort.
If you want to keep efficiency and reliability strong, we can also recommend service and maintenance based on your environment and usage. Regular support helps reduce surprises and keeps your system performing as expected season after season.
Mitsubishi Electric P-Series ductless systems are designed for larger spaces that need dependable, efficient heating and cooling. Below are a few key features that support steady performance, cleaner airflow, and better control for commercial, large residential, and demanding environments.
| Indoor Model | PKA-A24KA7 | PKA-A30KA7 | PKA-A36KA7 |
|---|---|---|---|
| Outdoor Model | PUZ-HA24NHA1 | PUZ-HA30NKA | PUZ-HA36NKA |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 14,600 to 30,000 [2½ tons] | 14,700 to 36,000 [3 tons] |
| Rated Heating Capacity (Btu/h) | 28,000 [2¼ tons] | 34,000 [2¾ tons] | 40,000 [3¾ tons] |
| SEER ♦ | 19.5 | 18.5 | 18.5 |
| HSPF (IV) ♦ | 10.6 | 9.6 | 10 |
| ENERGY STAR® | |||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -25 to 24 °C (Hyper Heating) | -25 to 24 °C (Hyper Heating) | -25 to 24 °C (Hyper Heating) |
| Indoor Model | PLA-A24EA7 | PLA-A30EA7 | PLA-A36EA7 | PLA-A42EA7 |
|---|---|---|---|---|
| Outdoor Model | PUZ-HA24NHA1 | PUZ-HA30NKA | PUZ-HA36NKA | PUZ-HA42NKA1 |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 14,600 to 30,000 [2½ tons] | 14,800 to 36,000 [3 tons] | 18,800 to 42,000 [3½ tons] |
| Rated Heating Capacity (Btu/h) | 28,000 [2¼ tons] | 34,000 [2¾ tons] | 40,000 [3¾ tons] | 54,000 [4½ tons] |
| SEER ♦ | 22 | 20 | 20 | 16 |
| HSPF (IV) ♦ | 11 | 10 | 10 | 10 |
| Energy Star | Certified | Certified | ||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C |
| Indoor Model | PCA-A24KA7 | PCA-A30KA7 | PCA-A36KA7 | PCA-A42KA7 |
|---|---|---|---|---|
| Outdoor Model | PUZ-HA24NHA1 | PUZ-HA30NKA | PUZ-HA36NKA | PUZ-HA42NKA |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 14,300 to 30,000 [2½ tons] | 14,900 to 34,000 [2¾ tons] | 16,600 to 42,000 [3½ tons] |
| Rated Heating Capacity (Btu/h) | 28,000 [2¼ tons] | 35,000 [2¾ tons] | 40,000 [3¾ tons] | 54,000 [4½ tons] |
| SEER ♦ | 18.5 | 17.9 | 18 | 15.5 |
| HSPF (IV) ♦ | 10.3 | 9.4 | 10.3 | 10 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C |
| Indoor Model | PEAD-A24AA7 | PEAD-A30AA7 | PEAD-A42KA7 |
|---|---|---|---|
| Outdoor Model | PUZ-HA24NHA1 | PUZ-HA30NKA | PUZ-HA42NKA1 |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 14,600 to 30,000 [2½ tons] | 17,100 to 42,000 [3½ tons] |
| Rated Heating Capacity (Btu/h) | 28,000 [2¼ tons] | 34,000 [2¾ tons] | 54,000 [4½ tons] |
| SEER ♦ | 17 | 18 | 15 |
| HSPF (IV) ♦ | 10.4 | 9.6 | 9.8 |
| Energy Star | Certified | ||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C |
| Indoor Model | PVA-A24KAA7 | PVA-A30AA7 | PVA-A36AA7 | PVA-A42EA7 |
|---|---|---|---|---|
| Outdoor Model | PUZ-HA24NHA1 | PUZ-HA30NKA | PUZ-HA36NKA | PUZ-HA42NKA1 |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 14,800 to 30,000 [2½ tons] | 15,500 to 36,000 [3 tons] | 17,000 to 42,000 [3½ tons] |
| Rated Heating Capacity (Btu/h) | 28,000 [2¼ tons] | 34,000 [2¾ tons] | 40,000 [3¾ tons] | 54,000 [4½ tons] |
| SEER ♦ | 19 | 18 | 18.2 | 15.4 |
| HSPF (IV) ♦ | 10.4 | 9.8 | 11.2 | 10 |
| Energy Star | Certified | Certified | ||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C | -25 to 24 °C |
| Indoor Model | PKA-A12HA7 | PKA-A18HA7 | PKA-A24KA7 | PKA-A30KA7 | PKA-A36KA7 |
|---|---|---|---|---|---|
| Outdoor Model | PUZ-A12NKA7 | PUZ-A18NKA7 | PUZ-A24NHA7 | PUZ-A30NHA7 | PUZ-A36NKA7 |
| Cooling Capacity (Btu/h) (Min to Max) | 5,800 to 12,000 [1 ton] | 8,000 to 18,000 [1½ tons] | 10,000 to 24,000 [2 tons] | 9,000 to 30,000 [2½ tons] | 16,000 to 36,000 [3 tons] |
| Heating Capacity (Btu/h) (Min to Max) | 5,500 to 18,000 [1½ tons] | 7,700 to 22,000 [1¾ tons] | 9,000 to 28,000 [2⅓ tons] | 8,900 to 34,000 [2¾ tons] | 18,200 to 40,000 [3⅓ tons] |
| SEER ♦ | 20.8 | 18.5 | 21.4 | 19.8 | 18.8 |
| HSPF (IV) ♦ | 10.2 | 10.2 | 11 | 9.9 | 9.2 |
| ENERGY STAR® | |||||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -11 to 21 °C | -11 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C |
| Indoor Model | PLA-A12EA7 | PLA-A18EA7 | PLA-A24EA7 | PLA-A30EA7 | PLA-A36EA7 | PLA-A42EA7 |
|---|---|---|---|---|---|---|
| Outdoor Model | PUZ-A12NKA7 | PUZ-A18NKA7 | PUZ-A24NHA7 | PUZ-A30NHA7 | PUZ-A36NKA7 | PUZ-A42NKA7 |
| Cooling Capacity (Btu/h) (Min to Max) | 5,800 to 12,000 [1 ton] | 8,000 to 18,000 [1½ tons] | 10,000 to 24,000 [2 tons] | 9,000 to 30,000 [2½ tons] | 16,000 to 36,000 [3 tons] | 16,000 to 42,000 [3½ tons] |
| Heating Capacity (Btu/h) (Min to Max) | 5,500 to 20,000 [1⅔ tons] | 7,900 to 23,000 [2 tons] | 9,000 to 29,000 [2½ tons] | 9,000 to 33,000 [2¾ tons] | 18,000 to 42,000 [3½ tons] | 18,000 to 48,000 [4 tons] |
| SEER ♦ | 27 | 24.6 | 24.2 | 22.8 | 21.8 | 21 |
| HSPF (IV) ♦ | 12.8 | 11 | 11.2 | 11.6 | 10.4 | 9.3 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | ||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -11 to 21 °C | -11 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C |
| Indoor Model | PCA-A24KA7 | PCA-A30KA7 | PCA-A36KA7 | PCA-A42KEA7 |
|---|---|---|---|---|
| Outdoor Model | PUZ-A24NHA7 | PUZ-A30NHA7 | PUZ-A36NKA7 | PUZ-A42NKA7 |
| Cooling Capacity (Btu/h) (Min to Max) | 10,000 to 24,000 [2 tons] | 9,000 to 30,000 [2½ tons] | 16,000 to 36,000 [3 tons] | 16,000 to 42,000 [3½ tons] |
| Heating Capacity (Btu/h) (Min to Max) | 8,600 to 28,000 [2⅓ tons] | 8,600 to 34,000 [2¾ tons] | 17,900 to 40,000 [3⅓ tons] | 18,100 to 48,000 [4 tons] |
| SEER ♦ | 21.2 | 19.6 | 19.1 | 17.6 |
| HSPF (IV) ♦ | 10.8 | 10 | 10.2 | 10.2 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C |
| Indoor Model | PEAD-A12AA7 | PEAD-A18AA7 | PEAD-A24AA7 | PEAD-A30AA7 | PEAD-A36AA7 | PEAD-A42AA7 |
|---|---|---|---|---|---|---|
| Outdoor Model | PUZ-A12NKA7 | PUZ-A18NKA7 | PUZ-A24NHA7 | PUZ-A30NHA7 | PUZ-A36NKA7 | PUZ-A42NKA7 |
| Cooling Capacity (Btu/h) (Min to Max) | 5,000 to 12,000 [1 ton] | 8,000 to 18,000 [1½ tons] | 10,000 to 24,000 [2 tons] | 9,000 to 30,000 [2½ tons] | 16,000 to 36,000 [3 tons] | 16,000 to 42,000 [3½ tons] |
| Heating Capacity (Btu/h) (Min to Max) | 5,800 to 18,000 [1½ tons] | 7,900 to 22,000 [1¾ tons] | 9,000 to 28,000 [2⅓ tons] | 8,800 to 34,000 [2¾ tons] | 18,200 to 40,000 [3⅓ tons] | 18,100 to 48,000 [4 tons] |
| SEER ♦ | 21.2 | 19.9 | 19.6 | 19.1 | 19.1 | 16.1 |
| HSPF (IV) ♦ | 10.2 | 10.2 | 10.8 | 10.8 | 9.9 | 10 |
| ENERGY STAR® | Certified | |||||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -11 to 21 °C | -11 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C |
| Indoor Model | PVA-A12AA7 | PVA-A18AA7 | PVA-A24AA7 | PVA-A30AA7 | PVA-A36AA7 | PVA-A42AA7 |
|---|---|---|---|---|---|---|
| Outdoor Model | PUZ-A12NKA7 | PUZ-A18NKA7 | PUZ-A24NHA7 | PUZ-A30NHA7 | PUZ-A36NKA7 | PUZ-A42NKA7 |
| Cooling Capacity (Btu/h) (Min to Max) | 4,800 to 12,000 [1 ton] | 7,000 to 18,000 [1½ tons] | 10,000 to 24,000 [2 tons] | 10,000 to 30,000 [2½ tons] | 14,600 to 36,000 [3 tons] | 15,000 to 42,000 [3½ tons] |
| Heating Capacity (Btu/h) (Min to Max) | 5,700 to 19,000 [1½ tons] | 7,700 to 23,000 [2 tons] | 12,000 to 28,000 [2⅓ tons] | 12,000 to 34,000 [2¾ tons] | 17,700 to 42,000 [3½ tons] | 18,100 to 48,000 [4 tons] |
| SEER ♦ | 21.4 | 20.2 | 20.5 | 19 | 19.3 | 18 |
| HSPF (IV) ♦ | 10.3 | 10.4 | 9.3 | 10 | 9.5 | 9.3 |
| ENERGY STAR® | Certified | |||||
| Power Supply | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz | 208/230 V, Single-Phase, 60 Hz |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C | -18 to 46 °C |
| Outdoor Temperatures for Heating (Min to Max) | -11 to 21 °C | -11 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C | -20 to 21 °C |
Talk to Go Ductless Inc. about ductless heating and cooling options for your home and get a clear estimate.