Enjoy precise, room by room comfort with Fujitsu General Airstage VRF solutions. Go Ductless Inc. plans the right system for your building and installs it with clean workmanship for quiet, efficient, year round performance.

Residential And Light Commercial

Fujitsu Halcyon is a smart choice for homes and light commercial spaces that want zoned comfort without ductwork, including condos, additions, basements, and rooms with hot or cold spots. Go Ductless Inc. helps you choose the right unit style and capacity, then plans a clean layout for steady heating and cooling with better room control.

Fujitsu AIRSTAGE Mini Splits

Fujitsu AIRSTAGE mini splits offer flexible capacity options for homes and light commercial spaces, with single zone and multi zone configurations designed for efficient, room by room comfort. Go Ductless Inc. helps you match the right indoor and outdoor system combination, then completes a clean installation focused on quiet operation and dependable performance.

Many Fujitsu AIRSTAGE systems use inverter technology to adjust output smoothly as conditions change, helping maintain stable temperatures while reducing energy waste. We guide you through layout, sizing, and placement so your mini split setup fits your space and comfort goals.

Warranty coverage can vary by model and installation requirements, and we help you understand the available options before you choose. If you are looking for Fujitsu branded ductless performance, AIRSTAGE is the current product family name used for Fujitsu ductless systems.

Fujitsu AIRSTAGE Mini Splits
Fujitsu General Airstage

Fujitsu General AIRSTAGE For Homes And Light Commercial

Fujitsu General AIRSTAGE is a smart choice for condos, townhomes, additions, basements, and homes with hot or cold spots that need better zone control. It is also a strong fit for small offices, studios, clinics, and retail spaces that want steady comfort without bulky ductwork.

Go Ductless Inc. helps you plan a layout that fits your space, whether you need one indoor head or several zones connected to one outdoor unit. We focus on clean line routing, proper mounting, and tidy finishing so the system looks as good as it performs.

If you are replacing baseboard heat, upgrading an older AC, or solving uneven temperatures, AIRSTAGE can be configured to match your goals. We make the selection and installation process simple from start to finish.

Clean Installation And Long Term Support From Go Ductless Inc.

A great ductless system starts with proper sizing, correct placement, and careful setup. Our team installs Fujitsu General AIRSTAGE systems with a clean process that prioritizes airflow, access for service, and a professional finish.

After installation, we walk you through how to use the controls, set schedules, and get the best comfort in each zone. We also share simple care tips and can provide maintenance support to help keep performance steady season after season.

From first consultation to final testing, we keep things clear and straightforward. If you want dependable cooling, heating support, and quiet performance, we are ready to help you get the right AIRSTAGE solution for your property.

Go Ductless Inc.|Fujitsu General Airstage

Fujitsu General AIRSTAGE Ductless Features

Fujitsu General AIRSTAGE systems are built for quiet, efficient comfort with flexible options for different rooms and layouts. Below are a few key features that support steady heating and cooling, better energy control, and everyday comfort you can count on.

Energy Savings Program (ESP)

ESP helps reduce energy waste by adjusting operation when rooms are unoccupied and returning to your preferred settings when you are back.

Inverter Technology

AIRSTAGE inverter systems ramp output up or down as needed to maintain steady comfort while using energy more efficiently.

FGLair App Remote Control

Control your system from your phone with the FGLair app, including temperature, modes, fan speed, schedules, and basic status alerts.

Extra Low Temperature Heating (XLTH)

XLTH models are designed for cold weather performance, helping deliver dependable heating when outdoor temperatures drop.

Fujitsu Ductless (Cooling & Heating) Systems Offered

Fujitsu LZAS/LZASB Series

Fujitsu LZAS/LZASB Series

Fujitsu General XLTH Graphic Fujitsu LZAH/LZAHB Series

XLTH Graphic LZAH/LZAHB Series

Fujitsu LMAS Series

Fujitsu LMAS Series

Fujitsu General XLTH Graphic Fujitsu LMAH/RLX Series

XLTH Graphic LMAH/RLX Series

Fujitsu LZAS/LZASB Series

Fujitsu LZAS/LZASB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LZAH/LZAHB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LMAS Series

Go Ductless Inc. | Fujitsu General Airstage

XLTH Graphic LMAH/RLX Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LZAS/LZASB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LZAH/LZAHB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LMAS Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LMAH/RLX Series

Go Ductless Inc. | Fujitsu General Airstage

XLTH Graphic LZAS/LZASB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LZAH/LZAHB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LMAS Series

Fujitsu Multi-Zone (Cooling & Heating) Systems Offered

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LZAS/LZASB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu General XLTH Graphic Fujitsu LZAH/LZAHB Series

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LMAS Series

Fujitsu LZAS/LZBS Wall Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ASUG09LZAS, ASUG12LZAS, ASUG15LZAS, ASUG09LZBS, ASUG12LZBS, ASUG15LZBS

ASUG09LZBS, ASUG12LZBS, ASUG15LZBS (B) Series equipped with built-in Wi-Fi.

Indoor Unit Model NumberASUG09LZ(A/B)SASUG12LZ(A/B)SASUG15LZ(A/B)S
Outdoor Unit Model NumberAOUG09LZAS1AOUG12LZAS1AOUG15LZAS1
Cooling Capacity (Btu/h) (Min to Max)3,100 to 12,0003,100 to 13,6003,100 to 18,400
Heating Capacity (Btu/h) (Min to Max)3,100 to 22,0003,100 to 22,1003,100 to 23,900
SEER ♦33.129.425.3
HSPF (IV) ♦14.21413.4
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-21 to 24°C-21 to 24°C-21 to 24°C

Fujitsu LZAH/LZAHB (XLTH) Wall Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ASUG09LZAS, ASUG12LZAS, ASUG15LZAS, ASUG09LZBS, ASUG12LZBS, ASUG15LZBS

ASUG09LZBS, ASUG12LZBS, ASUG15LZBS (B) Series equipped with built-in Wi-Fi.

Indoor Unit Model NumberASUG09LZ(A/B)SASUG12LZ(A/B)SASUG15LZ(A/B)S
Outdoor Unit Model NumberAOUG09LZAH1AOUG12LZAH1AOUG15LZAH1
XLTHXLTHXLTHXLTH
Cooling Capacity (Btu/h) (Min to Max)3,100 to 12,0003,100 to 13,6003,100 to 18,400
Heating Capacity (Btu/h) (Min to Max)3,100 to 22,0003,100 to 22,1003,100 to 23,900
SEER ♦33.129.425.3
HSPF (IV) ♦1413.813.3
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-26 to 24°C-26 to 24°C-26 to 24°C

Fujitsu LMAS Wall Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ASUH09LMAS, ASUH12LMAS

Go Ductless Inc. | Fujitsu General Airstage

ASUH18LMAS, ASUH24LMAS

Indoor Unit Model NumberASUH09LMAS (Gen H)ASUH12LMAS (Gen H)ASUH18LMASASUH24LMAS
Outdoor Unit Model NumberAOUH09LMAS1AOUH12LMAS1AOUH18LMAS1AOUH24LMAS1
Cooling Capacity (Btu/h) (Min to Max)3,400 to 10,9003,400 to 13,3007,000 to 20,0009,100 to 27,300
Heating Capacity (Btu/h) (Min to Max)2,800 to 15,0002,800 to 19,1008,000 to 29,0008,200 to 37,000
SEER ♦33.129.425.322.5
HSPF (IV) ♦14.21413.412
ENERGY STAR®CertifiedCertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-15 to 24°C-15 to 24°C-15 to 24°C-15 to 24°C

Fujitsu LMAS/RLX (XLTH) Wall Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ASUH09LMAS, ASUH12LMAS

Go Ductless Inc. | Fujitsu General Airstage

ASU18RLF, ASU24RLF

Go Ductless Inc. | Fujitsu General Airstage

ASU30RLE

Indoor Unit Model NumberASUH09LMAS (Gen H)ASUH12LMAS (Gen H)ASU18RLFASU24RLFASU30RLE
Outdoor Unit Model NumberAOUH09LMAH1AOUH12LMAH1AOU18RLXFWHAOU24RLXFWHAOU30RLXEH
XLTHXLTHXLTHXLTHXLTHXLTH
Cooling Capacity (Btu/h) (Min to Max)3,400 to 11,5003,400 to 13,3007,000 to 23,0009,900 to 27,3009,900 to 32,400
Heating Capacity (Btu/h) (Min to Max)2,800 to 16,0002,800 to 19,1007,000 to 29,0007,500 to 36,2008,000 to 37,500
SEER ♦26.5232019.518.7
HSPF (IV) ♦1312.510.410.511.7
ENERGY STAR®CertifiedCertifiedCertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C
Outdoor Temperatures for Heating (Min to Max)-26 to 24°C-26 to 24°C-26 to 24°C-26 to 24°C

Fujitsu LPAS Wall Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ASUH09LPAS, ASUH12LPAS, ASUH18LPAS, ASUH24LPAS

Go Ductless Inc. | Fujitsu General Airstage

ASUH18LMAS, ASUH24LMAS

Indoor Unit Model NumberASUH09LPASASUH12LPASASUH18LPASASUH24LPASASUH30LPASASUH36LPAS
Outdoor Unit Model NumberAOUH09LPAS1AOUH12LPAS1AOUH18LPAS1AOUH24LPAS1AOUH30LPAS1AOUH36LPAS1
Cooling Capacity (Btu/h) (Min to Max)3,300 to 10,8003,400 to 12,7004,000 to 19,0004,100 to 24,4009,900 to 32,4009,900 to 34,100
Heating Capacity (Btu/h) (Min to Max)2,600 to 12,5003,100 to 17,0002,800 to 24,0002,900 to 29,0008,700 to 33,0008,700 to 35,000
SEER ♦202020191818
HSPF (IV) ♦111111111111
ENERGY STAR®Certified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-15 to 24°C-15 to 24°C-15 to 24°C-15 to 24°C-15 to 24°C

Fujitsu RL2 (120 V) Wall Mounted Heat Pumps

Fujitsu RL2 (120 V) Wall Mounted Heat Pumps

ASU9RL2, ASU12RL2

Indoor Unit Model NumberASU9RL2ASU12RL2
Outdoor Unit Model NumberAOU9RL2AOU12RL2
Cooling Capacity (Btu/h) (Min to Max)1,700 to 10,7003,100 to 12,500
Heating Capacity (Btu/h) (Min to Max)1,700 to 12,0003,100 to 16,000
SEER ♦1616
HSPF (IV) ♦99
ENERGY STAR®
Power Supply120 v, Single-Phase, 60 Hz120 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-10 to 24°C

Fujitsu RLFF Floor Mounted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AGU9RLF, AGU12RLF, AGU15RLF

Indoor Unit Model NumberAGU9RLFAGU12RLFAGU15RLF
Outdoor Unit Model NumberAOU9RLFFAOU12RLFFAOU15RLFF
Cooling Capacity (Btu/h) (Min to Max)3,100 to 13,0003,100 to 14,3003,100 to 17,700
Heating Capacity (Btu/h) (Min to Max)3,100 to 18,8003,100 to 22,1003,100 to 23,900
SEER ♦2622.720.3
HSPF (IV) ♦12.611.611.2
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-21 to 24°C-21 to 24°C-21 to 24°C

Fujitsu LUAS Compact Cassette Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ACUH09LUAS1, ACUH12LUAS1, ACUH18LUAS1

Indoor Unit Model NumberAGU9RLFAGU12RLFAGU15RLF
Outdoor Unit Model NumberAOU9RLFFHAOU12RLFFHAOU15RLFFH
XLTHXLTHXLTHXLTH
Cooling Capacity (Btu/h) (Min to Max)3,100 to 13,0003,100 to 14,3003,100 to 17,700
Heating Capacity (Btu/h) (Min to Max)3,100 to 18,8003,100 to 19,5003,100 to 20,800
SEER ♦2622.720.3
HSPF (IV) ♦12.411.311
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-26 to 24°C-26 to 24°C-26 to 24°C

Fujitsu LUAS Compact Cassette Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ACUH09LUAS1, ACUH12LUAS1, ACUH18LUAS1

Indoor Unit Model NumberACUH09LUAS1ACUH12LUAS1ACUH18LUAS1
Outdoor Unit Model NumberAOUH09LUAS1AOUH12LUAS1AOUH18LUAS1
Cooling Capacity (Btu/h) (Min to Max)3,100 to 11,0003,100 to 13,6003,100 to 20,100
Heating Capacity (Btu/h) (Min to Max)3,100 to 16,0003,100 to 19,4003,100 to 23,900
SEER ♦22.522.120.8
HSPF (IV) ♦12.512.211.6
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-21 to 24°C

Fujitsu LUAS Slim Ducted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ACUH09LUAS1, ACUH12LUAS1, ACUH18LUAS1

Indoor Unit Model NumberADUH09LUAS1ADUH12LUAS1ADUH18LUAS1
Outdoor Unit Model NumberAOUH09LUAS1AOUH12LUAS1AOUH18LUAS1
Cooling Capacity (Btu/h) (Min to Max)3,100 to 11,0003,100 to 13,6003,100 to 20,100
Heating Capacity (Btu/h) (Min to Max)3,100 to 16,0003,100 to 19,4003,100 to 25,600
SEER ♦2020.220.2
HSPF (IV) ♦11.711.511.4
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-21 to 24°C-21 to 24°C-21 to 24°C

Fujitsu RGLX Medium-Static Ducted Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

ARUH12LUAS

Go Ductless Inc. | Fujitsu General Airstage

ARU18RGLX, ARU24RGLX, ARU30RGLX

Go Ductless Inc. | Fujitsu General Airstage

ARU36RGLX, ARU42RGLX, ARU48RGLX

Indoor Unit Model NumberARUH12LUASARU18RGLXARU24RGLXARU30RGLXARU36RGLXARU42RGLXARU48RGLX
Outdoor Unit Model NumberAOUH12LUAS1AOU18RGLXAOU24RGLXAOU30RGLXAOU36RGLXAOU42RGLXAOU48RGLX
Cooling Capacity (Btu/h) (Min to Max)3,100 to 13,6005,400 to 21,5005,400 to 29,0009,600 to 35,0009,600 to 39,00017,100 to 45,00017,100 to 50,000
Heating Capacity (Btu/h) (Min to Max)3,400 to 19,4005,400 to 25,6005,400 to 32,4009,200 to 39,0009,200 to 48,00018,000 to 51,00018,000 to 55,000
SEER ♦21.31917.516.516.717.816.6
HSPF (IV) ♦11.710.910.810.411.310.510.3
ENERGY STAR®CertifiedCertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C
Outdoor Temperatures for Heating (Min to Max)-21 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C

Fujitsu RGLX/LMAS Series Multi-Position Air Handler Unit Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AMUG24LMAS, AMUG30LMAS, AMUG36LMAS, AMUG48LMAS

Indoor Unit Model NumberAMUG24LMASAMUG30LMASAMUG36LMASAMUG48LMAS
Outdoor Unit Model NumberAOU24RGLXAOU30RGLXAOUG36LMAS1AOUG48LMAS1
Cooling Capacity (Btu/h) (Min to Max)5,400 to 29,0009,600 to 35,00013,000 to 38,00013,000 to 48,000
Heating Capacity (Btu/h) (Min to Max)5,400 to 32,4009,200 to 39,00011,000 to 52,00011,000 to 54,000
SEER ♦1918.51817
HSPF (IV) ♦10.710.310.210.2
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-20 to 46°C-20 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C

Fujitsu LUAHM Series Multi-Position Air Handler Unit Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AMUG30LMAS, AMUG36LMAS, AMUG48LMAS

Indoor Unit Model NumberAMUG30LMASAMUG36LMASAMUG48LMAS
Outdoor Unit Model NumberAOUH30LUAH1AOUH36LMAH1AOUH48LMAH1
XLTHXLTHXLTHXLTH
Cooling Capacity (Btu/h) (Min to Max)9,600 to 35,00013,000 to 39,00013,000 to 50,000
Heating Capacity (Btu/h) (Min to Max)9,200 to 39,00015,000 to 52,00015,000 to 55,000
SEER ♦19.117.316.3
HSPF (IV) ♦10.51110.2
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-21 to 46°C-21 to 46°C-21 to 46°C
Outdoor Temperatures for Heating (Min to Max)-26 to 24°C-26 to 24°C-26 to 24°C

Fujitsu RULX Series Universal Floor/Ceiling Heat Pumps

Fujitsu RULX Series Universal Floor/Ceiling Heat Pumps

ABU18RULX, ABU24RULX

Indoor Unit Model NumberABU18RULXABU24RULX
Outdoor Unit Model NumberAOU18RLXAOU24RLX
Cooling Capacity (Btu/h) (Min to Max)5,000 to 21,6005,000 to 27,300
Heating Capacity (Btu/h) (Min to Max)5,000 to 25,6005,000 to 29,000
SEER ♦1615
HSPF (IV) ♦8.58.5
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-18 to 46°C-18 to 46°C
Outdoor Temperatures for Heating (Min to Max)-10 to 24°C-10 to 24°C

Fujitsu RGLX Series Ceiling Cassette Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AUU18RGLX, AUU24RGLX with UTG-GCGF

Go Ductless Inc. | Fujitsu General Airstage

AUU30RGLX, AUU36RGLX, AUU42RGLX, AUU48RGLX with UTG-GCGF

Indoor Unit Model NumberAUU18RGLXAUU24RGLXAUU30RGLXAUU36RGLXAUU42RGLXAUU48RGLX
Outdoor Unit Model NumberAOU18RGLXAOU24RGLXAOU30RGLXAOU36RGLXAOU42RGLXAOU48RGLX
Cooling Capacity (Btu/h) (Min to Max)5,400 to 21,5005,400 to 29,0009,600 to 35,0009,600 to 39,00017,100 to 45,00017,100 to 50,000
Heating Capacity (Btu/h) (Min to Max)5,400 to 25,6005,400 to 32,4009,200 to 39,0009,200 to 48,00018,000 to 51,00018,000 to 55,000
SEER ♦21.42018.617.518.517.8
HSPF (IV) ♦10.910.811.511.29.710.6
ENERGY STAR®CertifiedCertified
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C-20 to 46°C
Outdoor Temperatures for Heating (Min to Max)-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C-20 to 24°C

* Black grille also available. Part No. UTG-LCGVCB.

Fujitsu RLXFZ Series Multi-Zone Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AOU18RLXFZ, AOU24RLXFZ

Go Ductless Inc. | Fujitsu General Airstage

AOU36RLXFZ

Go Ductless Inc. | Fujitsu General Airstage

AOU45RLXFZ

Outdoor Unit Model NumberAOU18RLXFZAOU24RLXFZAOU36RLXFZ1AOU45RLXFZ
Cooling Capacity (Btu/h) (Rated)18,00022,00035,20045,000
Heating Capacity (Btu/h) (Rated)22,00024,00036,40048,000
SEER ♦16 to 1815.5 to 1816 to 1817.7 to 19.7
HSPF (IV) ♦9 to 9.39 to 9.58.7 to 9.49.3 to 10.3
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-15 to 24°C-15 to 24°C-15 to 24°C-15 to 24°C

Fujitsu RLXFZH (XLTH) Series Multi-Zone Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

AOU18RLXFZH, AOU24RLXFZH

Go Ductless Inc. | Fujitsu General Airstage

AOU36RLXFZH

Outdoor Unit Model NumberAOU18RLXFZHAOU24RLXFZHAOU36RLXFZH
XLTHXLTHXLTHXLTH
Cooling Capacity (Btu/h) (Rated)18,00022,00035,200
Heating Capacity (Btu/h) (Rated)22,00025,00036,400
SEER ♦19 to 21.518 to 2018 to 20
HSPF (IV) ♦9 to 10.39 to 10.39.3 to 10.3
ENERGY STAR®
Power Supply208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz208/230 v, Single-Phase, 60 Hz
Outdoor Temperatures for Cooling (Min to Max)-10 to 46°C-10 to 46°C-10 to 46°C
Outdoor Temperatures for Heating (Min to Max)-26 to 24°C-26 to 24°C-26 to 24°C

* Black grille also available. Part No. UTG-LCGVCB.

Fujitsu Indoor Units for Multi-Split Heat Pumps

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LPAS Mirror Wall Mounted

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LUAS
Slim Duct

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu LUAS Compact Cassette

Go Ductless Inc. | Fujitsu General Airstage

Fujitsu RLF Floor
Mounted

LPAS Wall MountASUH07LPASASUH09LPASASUH12LPASASUH15LPASASUH18LPASASUH24LPAS
Rated Capacity (Btu/h)7,000 [½ tons]9,000 [¾ tons]12,000 [1 ton]15,000 [1¼ tons]18,000 [1½ tons]24,000 [2 tons]
LUAS Slim DuctADUH07LUAS1ADUH09LUAS1DADUH12LUAS1DADUH18LUAS1DADUH24LUAS1
Rated Capacity (Btu/h)7,000 [½ tons]9,000 [¾ tons]12,000 [1 ton]18,000 [1½ tons]24,000 [2 tons]
LUAS Compact CassetteACUH07LUAS1ACUH09LUAS1ACUH12LUAS1ACUH18LUAS1
Rated Capacity (Btu/h)7,000 [½ tons]9,000 [¾ tons]12,000 [1 ton]18,000 [1½ tons]
RLF Floor MountAGU9RLFAGU12RLFAGU15RLF
Rated Capacity (Btu/h)9,000 [¾ tons]12,000 [1 ton]18,000 [1½ tons]

Need A Ductless System You Can Trust?

Talk to Go Ductless Inc. about ductless heating and cooling options for your home and get a clear estimate.

Call Now Button