Bring quiet, efficient comfort to your space with Daikin ductless heating and cooling. Go Ductless Inc. helps you choose the right system and installs it with clean workmanship for dependable, room by room control.
Daikin ductless systems are designed to blend into your home or workspace while giving you precise control of comfort in each zone. Go Ductless Inc. supports the full process from planning and sizing to professional installation and ongoing service across Toronto and the GTA.
Daikin is a trusted name worldwide, with ductless systems used in homes and businesses across many countries. Their lineup is known for combining strong performance with a clean, modern look that fits today’s spaces.
At Go Ductless Inc., we help you choose the right Daikin ductless system for your layout, comfort goals, and budget. From single zone rooms to multi zone setups, we plan the details so your system runs smoothly from day one.
Daikin’s approach is built around dependable comfort and smart efficiency. With professional sizing and a clean installation, you get quiet operation, steady temperatures, and a better day to day experience in every season.
Daikin ductless systems are a smart choice when you want zoned comfort without adding ductwork. They work well for condos, additions, finished basements, and rooms that never feel quite right, plus small offices and retail spaces that need steady temperature control.
Go Ductless Inc. helps you choose the right unit style and capacity for your layout, then plans the best placement for smooth airflow and balanced comfort. You get a clean, modern look indoors and reliable performance that feels consistent from room to room.
If you are comparing single zone and multi zone options, we walk you through what makes sense for your space, budget, and comfort goals. The result is a ductless setup that runs quietly, responds quickly, and keeps comfort simple every day.
A great ductless system starts with proper planning and correct sizing. Go Ductless Inc. focuses on the details that matter, including clean line routing, solid mounting, and a tidy finished look that blends into your space.
After installation, we test the system settings, check airflow, and confirm smooth operation before we leave. We also explain basic controls and best practices so you can get the comfort you want without guesswork.
If you need ongoing support, we can help with maintenance guidance and service planning so your Daikin ductless system stays efficient and dependable over time. Our goal is simple: clean work, clear communication, and comfort you can trust.
Daikin ductless systems are built for quiet, efficient comfort with flexible options for different rooms and layouts. Below are a few key features that help deliver steady heating and cooling, cleaner airflow, and simple controls for everyday comfort.
| Indoor Unit Model Number | FTXM09VVJU | FTXM12VVJU | FTXM18VVJU | FTXM24VVJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RXM09VVJU | RXM12VVJU | RXM18VVJU | RXM24VVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 12,500 | 4,800 to 16,000 | 9,000 to 22,000 | 9,000 to 26,000 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 19,500 | 4,800 to 22,600 | 9,000 to 30,200 | 9,000 to 32,200 |
| SEER ♦ | 27.4 | 25.2 | 22.7 | 22 |
| HSPF (IV) ♦ | 13.8 | 13 | 12.5 | 12.5 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C |
| Indoor Unit Model Number | FTXR09TVJUW/S | FTXR12TVJUW/S | FTXR18TVJUW/S |
|---|---|---|---|
| Outdoor Unit Model Number | RX09RMVJU9A | RX12RMVJU9A | RX18RMVJU9A |
| Cooling Capacity (Btu/h) (Min to Max) | 4,500 to 10,600 | 4,500 to 12,800 | 5,100 to 18,500 |
| Heating Capacity (Btu/h) (Min to Max) | 4,100 to 14,600 | 4,100 to 15,800 | 5,800 to 21,200 |
| SEER ♦ | 18 | 17 | 14.5 |
| HSPF (IV) ♦ | 9.3 | 10 | 9.8 |
| ENERGY STAR® | |||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FTX09AXVJU | FTX12AXVJU | FTX18AXVJU | FTX24AXVJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RX09AXVJU | RX12AXVJU | RX18AXVJU | RX24AXVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 10,500 | 4,400 to 13,300 | 5,500 to 20,000 | 5,500 to 24,000 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 13,000 | 4,400 to 16,400 | 5,500 to 24,000 | 5,800 to 27,600 |
| SEER ♦ | 19 | 19 | 18.5 | 19 |
| HSPF (IV) ♦ | 10 | 10 | 9 | 9 |
| ENERGY STAR® | Certified | Certified | Certified | |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FTXB09AXVJU | FTXB12AXVJU | FTXB18AXVJU | FTXB24AXVJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RXB09AXVJU | RXB12AXVJU | RXB18AXVJU | RXB24AXVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 10,200 | 4,400 to 13,000 | 4,300 to 21,200 | 6,000 to 22,200 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 13,600 | 4,400 to 16,200 | 4,000 to 22,500 | 4,100 to 27,300 |
| SEER ♦ | 17 | 17 | 17 | 17 |
| HSPF (IV) ♦ | 9 | 9 | 9 | 9 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | 10 to 46°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FTX09NMVJUA | FTX12NMVJUA | FTX15NMVJUA | FTX18UVJU | FTX24UVJU |
|---|---|---|---|---|---|
| Outdoor Unit Model Number | RXL09QMVJUA | RXL12QMVJU9A | RXL15QMVJUA | RXL18UMVJUA | RXL24UMVJUA |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 10,900 | 4,400 to 13,300 | 5,800 to 18,400 | 9,000 to 21,600 | 9,000 to 25,800 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 16,000 | 4,400 to 18,800 | 5,800 to 24,600 | 9,000 to 28,000 | 9,000 to 32,000 |
| SEER ♦ | 20 | 20 | 20 | 20.3 | 20 |
| HSPF (IV) ♦ | 12.5 | 12 | 12.5 | 10.3 | 10.3 |
| ENERGY STAR® | |||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | 10 to 46°C | ||||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 15.5°C | -15 to 18°C | -15 to 15.5°C | -15 to 18°C | -15 to 18°C |
| Indoor Unit Model Number | FVXS09NVJU | FVXS12NVJU | FVXS15NVJU |
|---|---|---|---|
| Outdoor Unit Model Number | RXL09QMVJUA | RXL12QMVJU9A | RXL15QMVJUA |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 10,200 | 4,400 to 12,300 | 5,800 to 17,100 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 14,300 | 4,400 to 17,100 | 5,800 to 24,000 |
| SEER ♦ | 20 | 20 | 20 |
| HSPF (IV) ♦ | 11.7 | 11.4 | 11.3 |
| ENERGY STAR® | |||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -10.5 to 15.5°C | -10.5 to 18°C | -10.5 to 15.5°C |
| Indoor Unit Model Number | FDMQ12RVJU | FDMQ18RVJU | FDMQ24RVJU |
|---|---|---|---|
| Outdoor Unit Model Number | RXL12QMVJU9A | RXL18UMVJUA | RXL24UMVJUA |
| Cooling Capacity (Btu/h) (Rated) | 10,800 | 17,600 | 21,200 |
| Heating Capacity (Btu/h) (Rated) | 13,600 | 21,600 | 24,000 |
| SEER ♦ | 18 | 19.4 | 18.6 |
| HSPF (IV) ♦ | 10.8 | 10.3 | 10 |
| ENERGY STAR® | |||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C |
| Indoor Unit Model Number | FTX30NVJU | FTX36NVJU |
|---|---|---|
| Outdoor Unit Model Number | RX30NMVJUA | RX36NMVJUA |
| Cooling Capacity (Btu/h) (Min to Max) | 10,200 to 31,400 | 10,200 to 34,400 |
| Heating Capacity (Btu/h) (Min to Max) | 10,200 to 34,800 | 10,200 to 36,000 |
| SEER ♦ | 17.5 | 15.9 |
| HSPF (IV) ♦ | 9.3 | 9.2 |
| ENERGY STAR® | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | |
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FTXS09LVJU | FTXS12LVJU | FTXS15LVJU | FTXS18LVJU | FTXS24LVJU |
|---|---|---|---|---|---|
| Outdoor Unit Model Number | RXS09LVJU | RXS12LVJU | RXS15LVJU | RXS18LVJU | RXS24LVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 9,000 | 4,800 to 12,000 | 5,800 to 15,000 | 5,800 to 18,000 | 7,800 to 21,500 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 12,000 | 4,800 to 14,400 | 5,800 to 18,000 | 5,800 to 21,600 | 7,800 to 25,400 |
| SEER ♦ | 24.5 | 23 | 20.6 | 20.3 | 20 |
| HSPF (IV) ♦ | 12.5 | 12.5 | 11.6 | 11 | 10.6 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46°C | ||||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 15.5°C | -15 to 18°C | -15 to 15.5°C | -15 to 18°C | -15 to 18°C |
| Indoor Unit Model Number | FDXS09LVJU | FDXS12LVJU |
|---|---|---|
| Outdoor Unit Model Number | RXS09LVJU | RXS12LVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 8,500 | 4,800 to 11,500 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 10,000 | 4,800 to 11,500 |
| SEER ♦ | 15.1 | 15.5 |
| HSPF (IV) ♦ | 10.3 | 10.4 |
| ENERGY STAR® | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 46°C | |
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FDMQ09RVJU | FDMQ12RVJU | FDMQ15RVJU | FDMQ18RVJU | FDMQ24RVJU |
|---|---|---|---|---|---|
| Outdoor Unit Model Number | RX09RMVJU9A | RX12RMVJU9A | RX15RMVJUA | RX18RMVJU9A | RX24RMVJUA |
| Cooling Capacity (Btu/h) (Rated) | 9,000 | 10,800 | 14,400 | 17,600 | 21,800 |
| Heating Capacity (Btu/h) (Rated) | 10,900 | 13,600 | 18,000 | 21,600 | 24,000 |
| SEER ♦ | 17.8 | 19.4 | 20.2 | 18.5 | 18.6 |
| HSPF (IV) ♦ | 10.3 | 10.6 | 10.6 | 10.3 | 10 |
| ENERGY STAR® | Certified | Certified | Certified | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | ||||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FFQ09Q2VJU | FFQ12Q2VJU | FFQ15Q2VJU | FFQ18Q2VJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RX09RMVJU9A | RX12RMVJU9A | RX15RMVJUA | RX18RMVJU9A |
| Cooling Capacity (Btu/h) (Min to Max) | 4,600 to 11,000 | 4,600 to 13,300 | 5,100 to 16,200 | 5,100 to 21,800 |
| Heating Capacity (Btu/h) (Min to Max) | 4,600 to 14,000 | 4,600 to 16,800 | 5,200 to 16,300 | 5,400 to 21,800 |
| SEER ♦ | 20.9 | 20.2 | 20.7 | 19.3 |
| HSPF (IV) ♦ | 11.7 | 11.2 | 11 | 10.1 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C |
| Indoor Unit Model Number | FTK09AXVJU | FTK12AXVJU | FTK18AXVJU | FTK24AXVJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RK09AXVJU | RK12AXVJU | RK18AXVJU | RK24AXVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 10,200 | 4,400 to 13,300 | 5,500 to 20,000 | 5,500 to 24,000 |
| SEER ♦ | 19 | 19 | 19 | 19 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C |
| Indoor Unit Model Number | FTKB09AXVJU | FTKB12AXVJU | FTKB18AXVJU | FTKB24AXVJU |
|---|---|---|---|---|
| Outdoor Unit Model Number | RKB09AXVJU | RKB12AXVJU | RKB18AXVJU | RKB24AXVJU |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 13,600 | 4,400 to 16,200 | 4,000 to 22,500 | 4,100 to 27,300 |
| SEER ♦ | 17 | 17 | 17 | 17 |
| ENERGY STAR® | ||||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | 10 to 46°C |
| Indoor Unit Model Number | FTX30NVJU | FTX36NVJU |
|---|---|---|
| Outdoor Unit Model Number | RK30NMVJUA | RK36NMVJUA |
| Cooling Capacity (Btu/h) (Min to Max) | 10,200 to 31,400 | 10,200 to 34,400 |
| SEER ♦ | 18 | 16 |
| ENERGY STAR® | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 46°C |
| Indoor Unit Model Number | FTXS30LVJU | FTXS36LVJU |
|---|---|---|
| Outdoor Unit Model Number | RKS30LVJU | RKS36LVJU |
| Cooling Capacity (Btu/h) (Min to Max) | 4,400 to 9,000 | 4,800 to 12,000 |
| SEER ♦ | 19 | 18 |
| ENERGY STAR® | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) | -40 to 46°C |
| Outdoor Unit Model Number | 2MXL18QMVJU(A) | 3MXL24RMVJU(A) | 4MXL36TVJU |
|---|---|---|---|
| Cooling Capacity (Btu/h) (Rated) | 18,000 | 24,000 | 34,400 |
| Heating Capacity (Btu/h) (Rated) | 18,900 | 24,100 | 36,600 |
| SEER ♦ | 15.5 to 17 | 16 to 18 | 19.3 to 21.7 |
| HSPF (IV) ♦ | 9.25 to 10.3 | 10.35 to 12.5 | 10.15 to 11.2 |
| ENERGY STAR® | Certified (non-ducted) | Certified (non-ducted) | Certified (non-ducted) |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 46°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 15.5°C |
| Outdoor Unit Model Number | 2MXS18NMVJU(A) | 3MXS24RMVJU(A) | 4MXS36RMVJU(A) | 5MXS48TVJU | RMXS48LVJU |
|---|---|---|---|---|---|
| Cooling Capacity (Btu/h) (Rated) | 18,000 | 24,000 | 36,000 | 47,000 | 48,000 |
| Heating Capacity (Btu/h) (Rated) | 18,900 | 24,000 | 36,000 | 48,500 | 54,000 |
| SEER ♦ | 16.45 to 18.9 | 16 to 18 | 15.85 to 17.7 | 17.75 to 20.2 | 16.45 to 18.8 |
| HSPF (IV) ♦ | 9.45 to 10.7 | 10.35 to 12.5 | 10.2 to 12.2 | 9.85 to 11.1 | 10.45 to 11.3 |
| ENERGY STAR® | Certified (non-ducted) | Certified (non-ducted) | |||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 46°C | -5 to 46°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 15.5°C |






| AURORA Series Wall Mounted | FTXR09TVJUW/S | FTXR12TVJUW/S | FTXR18TVJUW/S | |
|---|---|---|---|---|
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 18,000 [1½ tons] | |
| LV Series Wall Mount | CTXS07LVJU | FTXS09LVJU | FTXS12LVJU | |
| Rated Capacity (Btu/h) | 7,000 [½ tons] | 9,000 [¾ tons] | 12,000 [1 ton] | |
| LV Series Slim Duct | CDXS07LVJU | FDXS09LVJU | FDXS12LVJU | |
| Rated Capacity (Btu/h) | 7,000 [½ tons] | 9,000 [¾ tons] | 12,000 [1 ton] | |
| FDMQ Series Ducted | FDMQ09RVJU | FDMQ12RVJU | FDMQ15RVJU | |
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 15,000 [1¼ tons] | |
| AURORA Series Floor Mounted | FVXS09NVJU | FVXS12NVJU | FVXS15NVJU | FVXS18NVJU |
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 15,000 [1¼ tons] | 18,000 [1½ tons] |
| VISTA Series Ceiling Cassette | FFQ09Q2VJU | FFQ12Q2VJU | ||
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] |
Talk to Go Ductless Inc. about ductless heating and cooling options for your home and get a clear estimate.