Quiet, efficient heating and cooling with flexible options for condos, homes, and additions. Go Ductless Inc. helps you choose the right LG setup and installs it with clean work and careful finishing.
LG Electronics is a great fit for residential and light commercial spaces, delivering quiet, efficient comfort with flexible single zone and multi zone options. Go Ductless Inc. helps you choose the right LG ductless system and completes a clean, professional installation for reliable heating and cooling with room by room control.
LG residential ductless systems are a smart choice for zoned comfort without adding ductwork. They work well in condos, older homes, renovations, basements, and rooms that never feel quite right.
With single zone and multi zone options, LG makes it easier to match the right indoor unit style to your layout. You get steady cooling in summer, dependable heating in cooler months, and better control room by room.
Go Ductless Inc. helps you compare unit types and capacities, plans the layout properly, and completes a professional installation that looks clean and performs the way it should.
A good ductless system starts with correct sizing and a layout that fits your space. We take the time to plan the line set route, indoor unit placement, and outdoor unit location for stable performance.
Our installs focus on neat finishing, safe electrical and drainage practices, and a clear walkthrough at the end. You will know how to use your settings, remotes, and comfort modes confidently.
If you want ongoing support, we can also recommend maintenance steps that help keep airflow strong, reduce wear, and protect efficiency over time.
LG offers a variety of indoor unit styles so your system can match the way you live. Wall mounted units are popular for bedrooms and living areas, while other styles can fit tighter layouts and specific comfort goals.
For multi room control, a multi zone setup can connect several indoor units to one outdoor unit. This helps keep comfort balanced across floors and reduces hot and cold spots.
Go Ductless Inc. will help you choose the configuration that makes sense for your home, your budget, and the level of control you want.
LG Electronics ductless systems are designed for quiet, efficient comfort with flexible options for different rooms and layouts. Below are a few key features that support steady heating and cooling, cleaner airflow, and smarter control for everyday comfort.
| Model | LA090HYV3 | LA120HYV3 | LA150HYV3 | LA180HYV3 | LA240HYV3 |
|---|---|---|---|---|---|
| LGRED® | Included | Included | Included | Included | Included |
| Indoor Unit Model Number | LAN090HYV3 | LAN120HYV3 | LAN150HYV3 | LAN180HYV3 | LAN240HYV3 |
| Outdoor Unit Model Number | LAU090HYV3 | LAU120HYV3 | LAU150HYV3 | LAU180HYV3 | LAU240HYV3 |
| Cooling Capacity (Btu/h) (Min to Max) | 1,023 to 13,000 | 1,023 to 13,785 | 3,070 to 21,000 | 3,070 to 29,515 | 3,070 to 30,000 |
| Heating Capacity (Btu/h) (Min to Max) | 1,023 to 20,472 | 1,023 to 22,178 | 3,070 to 25,200 | 3,070 to 32,000 | 3,070 to 36,200 |
| SEER ♦ | 27.5 | 25.5 | 25 | 24 | 22.5 |
| HSPF (IV) ♦ | 13.5 | 12.5 | 13.5 | 13 | 12.5 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 48°C | ||||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C |
| Model | LA090HSV5 | LA120HSV5 | LA150HSV5 |
|---|---|---|---|
| Indoor Unit Model Number | LAN090HSV5 | LAN120HSV5 | LAN150HSV5 |
| Outdoor Unit Model Number | LAU090HSV5 | LAU120HSV5 | LAU150HSV5 |
| Cooling Capacity (Btu/h) (Min to Max) | 1,023 to 12,625 | 1,023 to 13,785 | 3,070 to 29,515 |
| Heating Capacity (Btu/h) (Min to Max) | 1,023 to 17,061 | 1,023 to 22,178 | 3,070 to 38,898 |
| SEER ♦ | 23.5 | 22.7 | 21.5 |
| HSPF (IV) ♦ | 11.3 | 11.4 | 10.2 |
| ENERGY STAR® | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 48°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C |
| Model | LS090HSV5 | LS120HSV5 | LS150HSV5 | LS243HLV3 | LS303HLV3 | LS363HLV3 |
|---|---|---|---|---|---|---|
| Indoor Unit Model Number | LSN090HSV5 | LSN120HSV5 | LSN150HSV5 | LSN243HLV3 | LSN303HLV3 | LSN363HLV3 |
| Outdoor Unit Model Number | LSU090HSV5 | LSU120HSV5 | LSU150HSV5 | LSU243HLV3 | LSU303HLV3 | LSU363HLV3 |
| Cooling Capacity (Btu/h) (Min to Max) | 1,023 to 12,625 | 1,023 to 13,785 | 3,070 to 29,515 | 3,070 to 30,000 | 3,070 to 34,000 | 3,070 to 34,000 |
| Heating Capacity (Btu/h) (Min to Max) | 1,023 to 17,061 | 1,023 to 22,178 | 3,070 to 38,898 | 3,070 to 36,200 | 3,070 to 38,900 | 3,070 to 38,900 |
| SEER ♦ | 23.5 | 22.7 | 21.5 | 21.5 | 20 | 18.5 |
| HSPF (IV) ♦ | 11.3 | 11.4 | 10.2 | 12 | 11.5 | 11 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 48°C | |||||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C |
| Model | LQ090HV4 | LQ120HV4 |
|---|---|---|
| Indoor Unit Model Number | LQN090HV4 | LQN120HV4 |
| Outdoor Unit Model Number | LUU097HV | LUU127HV |
| Cooling Capacity (Btu/h) (Min to Max) | 4,270 to 11,500 | 4,500 to 13,460 |
| Heating Capacity (Btu/h) (Min to Max) | 4,600 to 13,000 | 5,970 to 15,000 |
| SEER ♦ | 21 | 20.8 |
| HSPF (IV) ♦ | 10.4 | 10.2 |
| ENERGY STAR® | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 48°C | |
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C |
| Model | LC098HV4 | LC128HV4 | LC188HV4 | LC188HHV4 |
|---|---|---|---|---|
| LGRED® | Included | |||
| Indoor Unit Model Number | LCN098HV4 | LCN128HV4 | LCN188HV4 | LCN188HV4 |
| Outdoor Unit Model Number | LUU097HV | LUU127HV | LUU189HV4 | LUU180HHV |
| Cooling Capacity (Btu/h) (Min to Max) | 3,600 to 9,900 | 3,400 to 12,400 | 7,700 to 24,800 | 7,200 to 24,800 |
| Heating Capacity (Btu/h) (Min to Max) | 4,400 to 12,100 | 2,800 to 15,500 | 6,500 to 23,400 | 6,500 to 23,700 |
| SEER ♦ | 21 | 20.8 | 21 | 20 |
| HSPF (IV) ♦ | 10.4 | 10.2 | 10.4 | 11.2 |
| ENERGY STAR® | Certified | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 48°C | -15 to 48°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C |
| Model | LC249HHV | LC369HHV | LC429HHV | LC489HHV |
|---|---|---|---|---|
| LGRED® | Included | Included | Included | Included |
| Indoor Unit Model Number | LCN249HV | LCN369HV | LCN429HV | LCN489HV |
| Outdoor Unit Model Number | LUU240HHV | LUU360HHV | LUU420HHV | LUU480HHV |
| Cooling Capacity (Btu/h) (Min to Max) | 9,600 to 30,000 | 14,400 to 46,000 | 16,800 to 49,000 | 19,200 to 53,000 |
| Heating Capacity (Btu/h) (Min to Max) | 10,800 to 33,000 | 16,000 to 46,000 | 18,000 to 57,600 | 19,000 to 61,000 |
| SEER ♦ | 21 | 21.5 | 19.5 | 17.5 |
| HSPF (IV) ♦ | 10.2 | 11 | 11.6 | 11.7 |
| ENERGY STAR® | Certified | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 48°C | |||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C |
| Model | LD097HV4 | LD127HV4 | LD187HV4 | LD187HHV4 |
|---|---|---|---|---|
| LGRED® | Included | |||
| Indoor Unit Model Number | LDN097HV4 | LDN127HV4 | LDN187HV4 | LDN187HV4 |
| Outdoor Unit Model Number | LUU097HV | LUU127HV | LUU189HV4 | LUU180HHV |
| Cooling Capacity (Btu/h) (Min to Max) | 3,600 to 9,900 | 4,640 to 12,760 | 7,400 to 21,100 | 7,200 to 22,000 |
| Heating Capacity (Btu/h) (Min to Max) | 5,600 to 15,400 | 6,400 to 17,600 | 6,800 to 21,800 | 6,800 to 24,000 |
| SEER ♦ | 18.5 | 19.6 | 18 | 18.8 |
| HSPF (IV) ♦ | 10.3 | 10.5 | 10 | 10 |
| ENERGY STAR® | Certified | Certified | Certified | |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) | -18 to 48°C | -15 to 48°C | ||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C |
| Model | LH248HV4 | LH368HV4 | LH248HHV4 | LH368HHV4 | LH428HHV | LH488HHV |
|---|---|---|---|---|---|---|
| LGRED® | Included | Included | Included | Included | ||
| Indoor Unit Model Number | LHN248HV | LHN368HV | LHN248HV | LHN368HV | LHN428HV | LHN488HV |
| Outdoor Unit Model Number | LUU249HV | LUU369HV | LUU240HHV | LUU360HHV | LUU420HHV | LUU480HHV |
| Cooling Capacity (Btu/h) (Min to Max) | 9,600 to 27,000 | 14,400 to 41,400 | 9,200 to 32,000 | 14,400 to 44,000 | 16,800 to 50,000 | 18,400 to 55,000 |
| Heating Capacity (Btu/h) (Min to Max) | 10,800 to 30,000 | 16,000 to 42,200 | 8,000 to 36,000 | 16,000 to 46,000 | 18,000 to 57,600 | 19,000 to 60,000 |
| SEER ♦ | 19 | 19 | 18.2 | 19 | 19 | 18.7 |
| HSPF (IV) ♦ | 10.5 | 9.7 | 10.8 | 10.2 | 10.9 | 11.2 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||||
| Outdoor Temperatures for Cooling (Min to Max) | -15 to 48°C | |||||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C | -25 to 18°C |
| Model | LV181HV4 | LV241HV4 | LV361HV4 | LV360HV4 | LV420HV | LV480HV |
|---|---|---|---|---|---|---|
| Indoor Unit Model Number | LVN181HV4 | LVN241HV4 | LVN361HV4 | LVN360HV4 | LVN420HV | LVN480HV |
| Outdoor Unit Model Number | LUU189HV | LUU249HV | LUU369HV | LUU368HV | LUU428HV | LUU488HV |
| Cooling Capacity (Btu/h) (Min to Max) | 7,200 to 24,000 | 9,600 to 30,000 | 14,400 to 39,000 | 14,000 to 44,000 | 17,000 to 48,000 | 18,000 to 53,000 |
| Heating Capacity (Btu/h) (Min to Max) | 8,000 to 24,000 | 19,800 to 30,000 | 16,000 to 43,000 | 15,000 to 47,000 | 18,000 to 55,000 | 19,000 to 60,000 |
| SEER ♦ | 19.2 | 19.5 | 18 | 18 | 17 | 16.5 |
| HSPF (IV) ♦ | 10.5 | 9.7 | 10.8 | 10.2 | 10.9 | 11.2 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | ||
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||||
| Outdoor Temperatures for Cooling (Min to Max) | -20 to 48°C | |||||
| Outdoor Temperatures for Heating (Min to Max) | -15 to 18°C | -25 to 18°C |
| Model | LV181HHV4 | LV241HHV4 | LV361HHV4 | LV420HHV | LV480HHV |
|---|---|---|---|---|---|
| LGRED® | Included | Included | Included | Included | Included |
| Indoor Unit Model Number | LVN181HV4 | LVN241HV4 | LVN361HV4 | LVN420HV | LVN480HV |
| Outdoor Unit Model Number | LUU180HHV | LUU240HHV | LUU360HHV | LUU420HHV | LUU480HHV |
| Cooling Capacity (Btu/h) (Min to Max) | 7,200 to 24,800 | 9,600 to 30,000 | 14,400 to 44,000 | 16,800 to 50,000 | 18,400 to 55,000 |
| Heating Capacity (Btu/h) (Min to Max) | 8,000 to 27,000 | 10,800 to 36,000 | 16,000 to 43,000 | 18,000 to 60,000 | 19,000 to 63,000 |
| SEER ♦ | 19.2 | 19.5 | 17.8 | 19.6 | 19 |
| HSPF (IV) ♦ | 10.5 | 11 | 10.7 | 11 | 10.5 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | Certified |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) | -15 to 48°C | ||||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C |


| Outdoor Unit Model | LMU180HV | LMU180HHV | LMU240HHV | LMU240HV | LMU30CHV | LMU300HHV | LMU36CHV |
|---|---|---|---|---|---|---|---|
| LGRED® | Included | Included | Included | ||||
| Cooling Capacity (Btu/h) (Min to Max) | 8,400 to 21,600 | 8,400 to 19,980 | 8,400 to 25,000 | 8,400 to 30,000 | 8,400 to 36,000 | 8,400 to 34,080 | 8,400 to 38,400 |
| Heating Capacity (Btu/h) (Min to Max) | 10,080 to 25,000 | 10,248 to 24,000 | 10,080 to 29,000 | 10,248 to 31,200 | 9,240 to 38,400 | 10,248 to 34,320 | 9,240 to 41,600 |
| SEER ♦ | 18.5 to 22.50 | 17.5 to 21 | 18.5 to 22.50 | 17 to 21 | 18.2 to 22 | 10.5 to 12.5 | 18.2 to 22 |
| HSPF (IV) ♦ | 9.6 to 11 | 9 to 10 | 9.8 to 11 | 9 to 10.7 | 9.7 to 10 | 9.5 to 11 | 9.7 to 10 |
| ENERGY STAR® | Certified | Certified (Non-ducted & Mixed) | Certified | Certified (Non-ducted & Mixed) | Certified (Non-ducted) | Certified (Non-ducted) | Certified (Non-ducted) |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | ||||||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 48°C | ||||||
| Outdoor Temperatures for Heating (Min to Max) | -20 to 18°C | -25 to 18°C | -20 to 18°C | -25 to 18°C | -20 to 18°C | -25 to 18°C | -20 to 18°C |
| Outdoor Unit Model | LMU361HHV | LMU421HHV | LMU481HV | LMU480HHV | LMU541HV | LMU601HV |
|---|---|---|---|---|---|---|
| LGRED® | Included | Included | Included | |||
| Cooling Capacity (Btu/h) (Min to Max) | 10,800 to 47,000 | 10,800 to 53,000 | 10,800 to 58,000 | 10,800 to 58,000 | 10,800 to 63,200 | 10,800 to 65,000 |
| Heating Capacity (Btu/h) (Min to Max) | 12,420 to 50,000 | 12,420 to 54,500 | 12,420 to 59,000 | 12,420 to 59,000 | 12,420 to 64,000 | 12,420 to 68,000 |
| SEER ♦ | 19 to 22 | 19 to 21.5 | 19 to 20.8 | 18.5 to 20.5 | 18.5 to 20.6 | 18.5 to 20.5 |
| HSPF (IV) ♦ | 10.5 to 11.5 | 10.5 to 11.5 | 10.5 | 10.5 to 11 | 10 | 10.5 to 11 |
| ENERGY STAR® | Certified | Certified | Certified | Certified | Certified | |
| Power Supply | 208/230 v, Single-Phase, 60 Hz | |||||
| Outdoor Temperatures for Cooling (Min to Max) | -10 to 48°C | |||||
| Outdoor Temperatures for Heating (Min to Max) | -25 to 18°C | -25 to 18°C | -20 to 18°C | -25 to 18°C | -20 to 18°C | -20 to 18°C |







| ARTCOOL Mirror Wall Mount | LAN090HSV5 | LAN120HSV5 | LAN180HSV5 | |||
|---|---|---|---|---|---|---|
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 18,000 [1½ tons] | |||
| DUALCOOL Wall Mount | LMN079HVT | LSN090HSV5 | LSN120HSV5 | LMN159HVT | LSN180HSV5 | LMN249HVT |
| Rated Capacity (Btu/h) | 7,000 [½ tons] | 9,000 [¾ tons] | 12,000 [1 ton] | 15,000 [1¼ tons] | 18,000 [1½ tons] | 24,000 [2 tons] |
| Floor Mounted Console | LQN090HV4 | LQN120HV4 | LMQN150HV | |||
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 15,000 [1¼ tons] | |||
| Ceiling Cassette | LMCN078HV | LCN098HV4 | LCN128HV4 | LCN188HV4 | ||
| Rated Capacity (Btu/h) | 7,000 [½ tons] | 9,000 [¾ tons] | 12,000 [1 ton] | 18,000 [1½ tons] | ||
| Low Static Pressure Ducted | LDN097HV4 | LDN127HV4 | LDN187HV4 | |||
| Rated Capacity (Btu/h) | 9,000 [¾ tons] | 12,000 [1 ton] | 18,000 [1½ tons] | |||
| High Static Pressure Ducted | LHN248HV | LHN368HV | ||||
| Rated Capacity (Btu/h) | 24,000 [2 tons] | 36,000 [3 tons] | ||||
| Vertical Air Handling Unit | LVN181HV4 | LVN241HV4 | LVN361HV4 | |||
| Rated Capacity (Btu/h) | 18,000 [1½ tons] | 24,000 [2 tons] | 36,000 [3 tons] |